End Station
THE END STATION:
- Two separate translation tables: to support the detector and the diffractometer (and the beam-conditioning elements). Both tables are projects developed in house by the Engineering Division.
- Beam conditioning elements: These are the elements right before the sample, they consist of the 12-foil attenuators, x-ray position monitors, slits, slow and fast shutter, kapton window.
- Diffractometer: Where the sample is rotated for data collection. The system includes a high accuracy omega axis (and a mini-kappa) and an on-axis viewing system.
- Automatic Sample Changer: The 6-axis robotic arm is used to manipulate both cryosamples and room-temperature crystallization plates. The Dewar is able to store 90 cryosamples.
- Detector. The main data collection detector is capable of recording 12 images per second.
|
Main components of the End-station (July 2011). |
Translation tables (in-house projects)
- Diffractometer table: holds the diffractometer and the beam conditioning elements. The table is based in a new design done in house based in flexures to increase stiffness and reliability. Allowed movements are vertical, transversal, yaw and pitch.
- Detector table: holds the detector. It is based in the same concept as the diffractometer table. Allowed movements of the detector are vertical, pitch, and longitudinal.
Diffractometer: MD2M (BRUKER)
Status: Installed.
- On-axis viewing system
- 2 μm sphere of confusion
- mini-kappa
- XYZ movable beam stop (in-house design)
Beam-conditioning Elements
Status: Almost all elements have been installed.
- Position monitors: both 4-quadrant CVD diamond (DECTRIS)
- 12-foil attenuators (ESRF type)
- Fast shutter (FPS400 CEDRAT)
- Slits (JJ-Xray ESRF type)
Automatic Sample Changer: CATS (IRELEC)
Status: Successfully installed and fully operating for SPINE pins. Crystallization plates being integrated.
- Robotic arm to mount/unmount SPINE pins
- The liquid N2 Dewar is able to store 90 samples
- Ability to scan Greiner, MRC and Fluidigm crystallization plates
- Barcode reading
Fluorescence detector: XFlash Detector 410-SA (BRUKER)
Status: Installed and integrated.
- To allow anomalous scattering experiments.
Detector: PILATUS 6M (DECTRIS)
Status: PILATUS 6M (DECTRIS) (http://dectris.com/sites/pilatus6m.html). Successfully installed, and operating. Now being integrated in the beamline control system
- 424x435 mm2 active area, 6Mpixels
- 1 Million counts dynamic range (20 bits)
- Delivery May 2011.
- Virtually noise free
Cryostream: 700 series (Oxford Cryosystems)
Status: Installed and working properly.
- 100K to 400K operation.
- 0.1 K stability.
- Cryoshutter.
Back to XALOC Homepage